Advanced configuration

The Advanced Options dialog of the GUI controls a large set of low-level parameters (domain generation, pseudo-CT mapping, thermal modelling, …). When scripting, you do not open that dialog — every one of those parameters is a plain entry in the bb.Config dictionary, so you set it directly:

bb = launch(...)
bb.Config['TrabecularProportion'] = 0.2       # override one advanced parameter
bb.Config['ElastixOptimizer'] = 'FiniteDifferenceGradientDescent'

Out of scope

Two operations reachable from the Advanced Options dialog — running the external PlanTUS tool and transducer calibration — need heavy user interaction and are not scriptable for now. The path/parameters they use (PlanTUSRoot, ConnectomeRoot, TxOptimizedWeights) are still ordinary bb.Config entries and are listed below for completeness.

When to set a parameter

Each parameter affects one of the pipeline steps. Set it before you trigger that step. The simplest, always-correct approach is to apply all your overrides right after launch() and before Step 1:

bb = launch(t1w=..., simbnibs=..., trajectory=..., transducer="CTX_500",
            frequency_khz=500, output_path="/data/out/")

# --- advanced overrides ---
bb.Config['bExtractAirRegions'] = True
bb.Config['TrabecularProportion'] = 0.2
bb.Config['BaselineTemperature'] = 37.0
bb.Config['HomogenousMediumValues']['Perfusion'] = 500.0

# --- then run the pipeline as usual ---
bb.Widget.CalculatePlanningMask.click()
wait_until(bb.Widget.tabWidget.isEnabled, timeout_ms=900_000)
check_no_error(bb)

bb.Config already contains every key below (initialised to the default value shown, or to the value you last saved in the GUI). You only assign the ones you want to change. The HomogenousMediumValues entry is a nested dictionary — set its members individually, e.g. bb.Config['HomogenousMediumValues']['Density'] = 1010.0.

Persistence

In the GUI, changing an advanced option persists to the next session. In a script, assigning to bb.Config only affects the current run.

Resetting to defaults

By default a scripted run inherits the advanced parameters from your previous session (the same values the GUI would show), so behaviour stays consistent with what you last configured. This is the default and nothing resets on its own.

When you instead want a deterministic, known state — e.g. for regression testing — reset every advanced parameter to its default with reset_advanced_config(bb). It is opt-in: you must call it explicitly.

bb = launch(...)
reset_advanced_config(bb)                 # every advanced param -> its default
bb.Config['TrabecularProportion'] = 0.2   # then apply only the overrides you need

reset_advanced_config restores every key listed on this page (including the nested HomogenousMediumValues and the per-transducer TxOptimizedWeights) to the defaults shown, mirroring the dialog's Reset to defaults button.


Domain generation (Step 1)

bb.Config key Default Description
ElastixOptimizer 'AdaptiveStochasticGradientDescent' Elastix optimizer for CT/ZTE/PETRA → T1W coregistration. Alternatives that help difficult CT→T1W cases: 'FiniteDifferenceGradientDescent', 'QuasiNewtonLBFGS'.
TrabecularProportion 0.8 Fraction of bone (along the line of sight) modelled as trabecular. Lower it (e.g. 0.1–0.2) for thin bone such as the parietal.
bSegmentBrainTissue False Use SimNIBS segmentation of white/grey matter and CSF with tissue-specific acoustic/thermal properties. Requires SimbNINBSRoot.
bForceUseBlender False Force Blender for constructive solid geometry instead of pycork (works around rare pycork crashes).
bApplyBOXFOV False Enable a manual sub-volume (box field of view) instead of the automatic one.
FOVDiameter 200.0 Manual FOV diameter (mm); used when bApplyBOXFOV is True.
FOVLength 400.0 Manual FOV length (mm); used when bApplyBOXFOV is True.
bExtractAirRegions True Create air-region masks (CT/PETRA/ZTE). Recommended to model far-field standing waves.
bDisableCTMedianFilter False Disable the median filter applied to the CT during processing.

Pseudo-CT mapping — CT / ZTE / PETRA (Step 1)

bb.Config key Default Description
bInvertZTE False Set True for inverted ZTE images (e.g. GE oZTEo), otherwise processing errors.
PetraNPeaks 2 Number of histogram bins used in PETRA bone selection (matches UCL's petra-to-ct).
PetraMRIPeakDistance 50 Minimal distance between PETRA histogram bins.
bGeneratePETRAHistogram False Also generate the PETRA histogram (as in petra-to-ct).
ZTESlope -2085.0 Slope of the linear ZTE-signal → pseudo-CT (HU) conversion.
ZTEOffset 2329.0 Offset of the linear ZTE → pseudo-CT conversion.
PETRASlope -2080.0 Slope of the linear PETRA-signal → pseudo-CT conversion.
PETRAOffset 2133.2 Offset of the linear PETRA → pseudo-CT conversion.

Adjust the slope/offset only if you have re-fitted the ZTE/PETRA → pseudo-CT relationship for your site.


Simulation & thermal

bb.Config key Default Affects Description
BaselineTemperature 37.0 Step 3 Baseline (body) temperature in °C for the thermal simulation.
LimitBHTEIterationsPerProcess 100 Step 3 Cap on bio-heat-transfer-equation iterations per process (memory/performance tuning).
bForceNoAbsorptionSkullScalp False Step 2/3 Force zero acoustic absorption in skull and scalp (verification/benchmarking).

Homogeneous medium (verification / benchmarking)

Replace the segmented head with a single homogeneous medium — useful for verification and benchmarking against analytical or reference solutions.

bb.Config key Default Description
bForceHomogenousMedium False Enable the homogeneous medium. When False, the values below are ignored.

When enabled, the medium properties come from the nested bb.Config['HomogenousMediumValues'] dictionary:

HomogenousMediumValues[...] Default Units Description
'Density' 1000.0 kg/m³ Mass density.
'LongSoS' 1500.0 m/s Longitudinal speed of sound.
'LongAtt' 5.0 Np/m/MHz Longitudinal attenuation.
'ShearSoS' 0.0 m/s Shear speed of sound.
'ShearAtt' 0.0 Np/m/MHz Shear attenuation.
'ThermalConductivity' 0.5 W/m/°C Thermal conductivity.
'SpecificHeat' 3583.0 J/kg/°C Specific heat capacity.
'Perfusion' 555.0 ml/min/kg Blood perfusion.
'Absorption' 0.85 – Absorption fraction (of attenuation converted to heat).
'InitTemperature' 37.0 °C Initial temperature.
bb.Config['bForceHomogenousMedium'] = True
hm = bb.Config['HomogenousMediumValues']
hm['Density'] = 1000.0
hm['LongSoS'] = 1500.0
hm['LongAtt'] = 5.0

Output / debugging

bb.Config key Default Description
bSaveStress False Also save the acoustic stress field from Step 2.
bSaveDisplacement False Also save the acoustic displacement field from Step 2.

External-tool roots

These are folder paths used by optional integrations. The operations that use them (PlanTUS, brain segmentation, calibration) are not scriptable here, but the paths are ordinary bb.Config entries.

bb.Config key Default Description
SimbNINBSRoot '...' SimNIBS installation root, required when bSegmentBrainTissue is True.
PlanTUSRoot '...' PlanTUS installation root (PlanTUS operation not scriptable).
ConnectomeRoot '...' Connectome Workbench root (used by PlanTUS).
TxOptimizedWeights {tx: '' , …} Per-transducer path to a calibration .h5 file. Dictionary keyed by transducer name; see Tx calibration.